{"title":"TwinFlex Fire Panels","description":"\u003cp\u003eFike\u003c\/p\u003e","products":[{"product_id":"fike-505-0002-twinflexpro-2-zone-bi-wire-conventional-fire-alarm-panel","title":"Fike 505-0002 | TwinflexPro² 2 Zone Bi-Wire Conventional Fire Alarm Panel","description":"\u003cp\u003eThe Fike 505-0002 Twinflex Pro² 2 Zone bi-wire fire alarm panel is an adaptable, cost-effective two-wire fire alarm system.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDevices are connected to this panel via Twinflex data protocol communication. Using highly intelligent systems, this panel can differentiate between smoke detectors, heat detectors and manual call point alarms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen purchasing your Fike bi-wire panel, it is important to note that up to 32 devices can be connected per circuit and these panels can be sold in 2,4 and 8 zone versions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKnown in the industry for its \u003c\/span\u003e\u003cspan\u003estate-of-the-art technology, \u003c\/span\u003ethe Twinflex Pro\u003cspan\u003e is \u003c\/span\u003e\u003cspan\u003edesigned for ease of use and reliability. Among other key features, the \u003c\/span\u003eversatility of this fire alarm panel is unmatched.\u003c\/p\u003e\n\u003cp\u003eThis panel uses the famous Fike ASD multipoint detection system meaning this whole system can be installed using only one pair of wires per zone.\u003c\/p\u003e\n\u003cp\u003eA Fike fire alarm panel is able to monitor each zone for device faults, end of line faults, short circuit faults and even detector head removals. Panel storage allows for 500 event logs to be stored along with day\/night modes and 72-hour battery standby times.\u003c\/p\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFike 505-0002 Twinflex Pro²\u003c\/li\u003e\n\u003cli\u003e4 line x 20 character LCD display\u003c\/li\u003e\n\u003cli\u003eAbility to differentiate between call point or detector alarms\u003c\/li\u003e\n\u003cli\u003eCheckpoint alarm verification procedure\u003c\/li\u003e\n\u003cli\u003eHighlighted selection menu\u003c\/li\u003e\n\u003cli\u003eEvent log storing up to 500 events\u003c\/li\u003e\n\u003cli\u003e3 Enhanced test modes\u003c\/li\u003e\n\u003cli\u003eAllows detectors and sounders to be installed on the same pair of wires\u003c\/li\u003e\n\u003cli\u003eUp to 32 devices per zone\u003c\/li\u003e\n\u003cli\u003eBuilt-in EOL capability in all devices\u003c\/li\u003e\n\u003cli\u003e7 modes of detection\u003c\/li\u003e\n\u003cli\u003eRequires 2 x 3.2Ah batteries\u003c\/li\u003e\n\u003cli\u003eAdditional battery box available to fit 2 x 7Ah batteries.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":43114454352051,"sku":"505-0002","price":271.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0550\/4938\/8211\/files\/FIK-505-0002_616x616_a3424120-a8ef-4f37-a4b8-ae6e047c021b.webp?v=1709558116"},{"product_id":"fike-twinflexpro2-two-wire-4-zone-fire-panel","title":"Fike TwinFlexPro2 Two Wire 4 Zone Fire Panel","description":"\u003cp data-mce-fragment=\"1\"\u003eThe TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 2,4 \u0026amp; 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector, heat detector and a manual call point alarm.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe panel also monitors each zone for detector head removal, device fault, End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits, a volt free common fire relay and a volt free common fault relay. There are also two multifunction latching\/non-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe panel features a 500-event log, day\/night mode, alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fike’s Twinflex devices, with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUnlike most conventional fire alarm systems, which require separate pairs of cables for detector zones and sounder circuits, the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e4 line x 20 character LCD display\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAbility to differentiate between smoke detector, heat detector or a manual call point alarms\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAlarm confirmation feature\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAvailable in 2, 4, and 8 zone panel versions\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRS485 Connection to up to 8 Repeater panels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHighlighted selection menu\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEvent log storing up to 500 events\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3 enhanced test modes\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAllows detectors and sounders to be installed on the same pair of wires\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUp to 32 devices per zone\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBuilt-in EOL capability in all devices\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e7 modes of detection\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eZone can be configured to day\/night detection mode\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDelay programming options\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":43114567663795,"sku":"(505-0004)","price":304.71,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0550\/4938\/8211\/files\/FIK-505-0002_616x616_6fed2e1a-a1b4-4f77-b68a-6b9288f1b328.webp?v=1709560293"},{"product_id":"fike-twinflexpro2-two-wire-8-zone-fire-panel-505-0008","title":"Fike TwinFlexPro2 Two Wire 8 Zone Fire Panel (505-0008)","description":"\u003cp data-mce-fragment=\"1\"\u003eThe TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 2,4 \u0026amp; 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector, heat detector and a manual call point alarm.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe panel also monitors each zone for detector head removal, device fault, End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits, a volt free common fire relay and a volt free common fault relay. There are also two multifunction latching\/non-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe panel features a 500-event log, day\/night mode, alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fike’s Twinflex devices, with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUnlike most conventional fire alarm systems, which require separate pairs of cables for detector zones and sounder circuits, the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e4 line x 20 character LCD display\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAbility to differentiate between smoke detector, heat detector or a manual call point alarms\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAlarm confirmation feature\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAvailable in 2, 4, and 8 zone panel versions\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRS485 Connection to up to 8 Repeater panels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHighlighted selection menu\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEvent log storing up to 500 events\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3 enhanced test modes\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAllows detectors and sounders to be installed on the same pair of wires\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUp to 32 devices per zone\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBuilt-in EOL capability in all devices\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e7 modes of detection\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eZone can be configured to day\/night detection mode\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDelay programming options\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":43114572906675,"sku":"505-0008","price":420.44,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0550\/4938\/8211\/files\/FIK-505-0002_616x616_d22d75e5-a4fd-46de-9d5f-540a48ef9b41.webp?v=1709560448"}],"url":"https:\/\/www.moretonalarms.com\/collections\/twinflex-fire.oembed","provider":"Moreton Alarms Trade","version":"1.0","type":"link"}